PRBS Stream Diagnosis
Function
Diagnose the communication signal quality of hardware links by sending and receiving PRBS streams to and from the RoCE network port of the NPU.
- CDR loopback: See Test Principle.
- Fiber optic circulator: See Test Principle.
Item |
Diagnosis Duration (Atlas A2 Training/Inference Products) |
Diagnosis Duration (Atlas A3 Training/Inference Products) |
Whether NPU Training or Inference Is Affected |
Application Scenario |
|---|---|---|---|---|
PRBS stream diagnosis |
3–10 seconds |
2–5 minutes |
Yes |
Locates the signal quality problem of the RoCE network port. |
Parameters
Table 2 lists only test-specific parameters. For details about other common parameters, see Common Parameters.
Parameter |
Description |
Mandatory |
|---|---|---|
[-i, --items] |
Specifies the diagnosis check item.
|
Yes |
[-td, --td, --trans-duration] |
Specifies the duration required by the PRBS stream test on the RoCE port.
|
No |
Example
ascend-dmi -dg -i prbs -q
Example of setting RoCE PRBS stream test duration to 5:
1 2 3 4 5 6 7 8 9 | [***@***]# ascend-dmi -dg -i prbs --td 5 -q Summary: Arch: aarch64 Mode: ****** Time: 20250530-10:43:21 Hardware: prbs: PASS |
Fault Check Items
Command Output |
Description |
|---|---|
IMPORTANT_WARN |
Important warning. The RoCE port has bit errors and the BER is greater than 10-5. Contact Huawei technical support. |
SKIP |
The current product or scenario does not support this function. |
PASS |
The stream test is passed. The signal quality of the RoCE port is normal. (The BER is less than 10-5.) |
FAIL |
|