Instructions

The following table lists the supported traffic sending modes and usage methods for stream tests.

Table 1 Ascend 950PR and 950DT products

Test Item

Supported Stream Test Mode

Instructions

One-click stream test

UB direct-connect links

When the command for one-click stream test is executed, Ascend DMI automatically sends and receives streams of all lanes on the specified device. After a period of time, the streams are closed and the result is queried.

Customized stream test

Stream test via an external fiber optic circulator (loopback plug) and direct NPU connection. Only UBoE ports are supported.

The customized stream test separates steps for one-click stream test, allowing you to flexibly control the TX and RX directions.

Cross-server stream test

NPUs of the two servers are interconnected through UB FullMesh.

Use MPI to start the Ascend DMI process on the two servers, send streams to specified NPUs, and query the result.

Table 2 Other products

Test Item

Supported Stream Test Mode

Instructions

One-click stream test

Stream test in a CDR loopback or via a fiber optic circulator

When the command for one-click stream test is executed, Ascend DMI automatically sends and receives streams of all lanes on the specified device. After a period of time, the streams are closed and the result is queried.

Customized stream test

Stream test in a CDR loopback, via a fiber optic circulator, or through direct NPU connections

The customized stream test separates steps for one-click stream testing, allowing you to flexibly control the TX and RX directions and specify the specific lane for stream testing.