Containerized Applications Fail to Be Upgraded on the Atlas 500 AI Edge Station (Model 3000) and a Message "Incorrect params" Is Displayed

Symptom

A containerized application fails to be upgraded on the Atlas 500 AI edge station (model 3000) WebUI, and the message "Incorrect params" is displayed, as shown in the following figure.

Possible Causes

The request contains unsupported parameters. For example, a containerized application with the root permission has been deployed in an earlier version and then is upgraded in a later version.

Procedure

  1. Delete the containerized application that contains unsupported parameters on the WebUI.
  2. Set parameters properly by referring to "Configuration Process > Deploying and Updating Applications on the Atlas 500 AI Edge Station (Model 3000) WebUI" in the MindX Edge Application Deployment Guide, and then deploy the containerized application.