"waiting for finish" Is Continuously Printed
Symptom
NNRT 7.0.0, MindCluster ToolBox 6.0.RC2, Toolkit 8.0.RC2, and kernel 8.0.RC2 are installed in the environment. When ascend-dmi --dg -i aicore -s -q is executed to perform the stress test, the error message "waiting for finish" is displayed, and plog reports that the operator configuration file cannot be found.
Possible Causes
NNRT 7.0.0 does not match the kernel version. As a result, the OPP cannot be found, and "waiting for finish' is continuous refreshed.
Solution
Uninstall Toolkit and NNRT, and reinstall Toolkit, then kernel, and finally NNRT of a matched version.
Parent topic: AICORE Diagnosis/Stress Test