hi_isp_calc_flicker_input

Description

Defines the input parameter for calculating the power frequency flicker.

Definition

typedef struct {
    hi_u32 lines_per_second;
} hi_isp_calc_flicker_input;

Members

Member

Description

lines_per_second

Maximum number of exposure lines in one second at the current timing.

Value range: [0x1F4,0xFFFFFFFF]. Default value: 0

Restrictions

  • lines_per_second indicates the maximum number of exposure lines in one second. For example, if the maximum exposure time of a frame is 1125 lines and the frame rate is 30 fps, then lines_per_second = 1125 x 30. Generally, the value of this parameter is also two times lines_per500ms of hi_isp_exp_info.
  • Note that the time of a line must be the same as that of the readout timing of a line. Generally, the time of the exposure lines of a sensor is the same as that of one readout line. However, the time of each readout line of some sensors is the time of two exposure lines. In this case, you need to divide the line count by 2 to obtain the actual value of lines_per_second. The rule applies.