aclvencChannelDescParamType

The Atlas training products does not support this enumeration.

The Atlas A2 products does not support this enumeration.

The Atlas A3 products does not support this enumeration.

VENC Channel Attribute Type

Description

ACL_VENC_THREAD_ID_UINT64 = 0

Callback thread ID.

Do not pass the same thread ID for subscribing to VENC callback functions on different devices in the same process.

ACL_VENC_CALLBACK_PTR = 1

Callback function.

ACL_VENC_PIXEL_FORMAT_UINT32 = 2

Image format.

  • PIXEL_FORMAT_YUV_SEMIPLANAR_420
  • PIXEL_FORMAT_YVU_SEMIPLANAR_420

ACL_VENC_ENCODE_TYPE_UINT32 = 3

Video coding protocol.

For details, see acldvppStreamFormat.

ACL_VENC_PIC_WIDTH_UINT32 = 4

Input image width.

ACL_VENC_PIC_HEIGHT_UINT32 = 5

Input image height.

ACL_VENC_KEY_FRAME_INTERVAL_UINT32 = 6

Key frame interval. Must be in the range of [1, 65536].

ACL_VENC_BUF_ADDR_PTR = 7

Pointer address of the encoding output buffer.

ACL_VENC_BUF_SIZE_UINT32 = 8

Size of the encoding output buffer, in bytes.
NOTE:

On Atlas inference products, this parameter defaults to 8 MB if not specified otherwise, and reaches at least 5 MB if specified.

On Atlas 200I/500 A2 inference products, this parameter defaults to 8 MB if not specified otherwise, and reaches at least 5 MB if specified.

ACL_VENC_RC_MODE_UINT32 = 9

Bit rate control mode.
  • 0: default mode
  • 1: variable bit rate (VBR) mode
  • 2: constant bit rate (CBR) mode
NOTE:

If this attribute is not set, the default value 0 is used.

For Atlas 200I/500 A2 inference products, the default value 0 indicates the VBR mode.

For Atlas inference products, the default value 0 indicates the VBR mode.

ACL_VENC_SRC_RATE_UINT32 = 10

Frame rate of the input stream (FPS).

For Atlas 200I/500 A2 inference products, the value is 0 or in the range of [1, 240].

For Atlas inference products, the value is 0 or in the range of [1, 240].

If it is not set or set to 0, the default value 30 is used. If the difference between the value of this parameter and the actual frame rate of the input stream is too large, the output bit rate is affected.

ACL_VENC_MAX_BITRATE_UINT32 = 11

Output bit rate (kbit/s).

For Atlas 200I/500 A2 inference products, the value range is [2, 614400]. The default value is 2000. If it is set to 0, the default value 2000 is used.

For Atlas inference products, the value range is [2, 614400]. The default value is 2000. If it is set to 0, the default value 2000 is used.

ACL_VENC_MAX_IP_PROP_UINT32 = 12

I-frame to P-frame bit allocation ratio within a GOP. Must be 0 or within the range of [1, 100]. The default value is 80 in VBR mode or 70 in CBR mode. If it is set to 0, the default value is used.