vdec_stop_recv_stream

Applicable Products

Product

Supported (√/x)

Ascend 950PR&950DT products

√

Atlas A3 products

√

Atlas A2 products

√

Atlas training products

x

Atlas inference products

√

Atlas 200I/500 A2 inference products

√

Description

Stops receiving the streams sent by the user. This API must be called before the decoding channel is destroyed.

Prototype

  • C Prototype
    1
    hi_s32 hi_mpi_vdec_stop_recv_stream(hi_vdec_chn chn);
    
  • Python Function
    1
    ret = acl.himpi.vdec_stop_recv_stream(chn)
    

Parameters

Parameter

Description

chn

Int, decoding channel ID.

Return Values

Return Value

Description

ret

ret: int, error code.

Constraints

  • Ensure that a channel has been created. Otherwise, the error code HI_ERR_VDEC_UNEXIST is returned.
  • If acl.himpi.vdec_send_stream is called after this API call, a failure is returned.
  • Repeated calls to this API return successful responses.

Reference

For the API call sequence, see JPEGE and VENC.