No display over the HDMI
Application Scenario
- Service scenario: display over the HDMI
- Applicable processor:
Atlas 200I/500 A2 inference product - Processor forms: EP and RC
Symptom
When the VO module and HDMI display signals, the HDMI displays no signal and no error log is reported.
Possible Cause
The possible causes are as follows:
- At the end of the test case, hi_mpi_hdmi_start is not called to enable a specific HDMI, or the HDMI is incorrectly enabled.
- The HDMI attributes and information frame parameters are incorrectly set in the test case.
- The monitor does not support the current resolution.
Solution
- Check whether hi_mpi_hdmi_start is called to enable a specific HDMI or whether the HDMI is incorrectly enabled.
- Check parameters in the test case. For example, check whether video_format under avi infoframe, timing_mode under hi_hdmi_attr, and pix_clk are consistent with outputs of the VO module.
- Read the EDID information of the current monitor to check whether the monitor supports the current resolution. If not, replace it with a monitor that supports the resolution.
- Execute the test case that displays signals over the HDMI again.
Parent topic: HDMI Data Display Issues