This feature provides parameter plane connectivity checks, real-time monitoring, and proactive risk warnings. By streamlining fault diagnostics and demarcation, it pre-warns network issues and sub-healthy faults and ensures the long-term stability of the cluster network.
Currently, only integration with ClusterD and NodeD for online deployment is supported. For details about how to deploy ClusterD and NodeD, see Installation and Deployment.
kubectl apply -f pingmesh-config.yaml
Command output:
configmap/pingmesh-config created
kubectl edit cm -n cluster-system pingmesh-config
Parameter |
Value |
Description |
|---|---|---|
app |
pingmesh |
Key of a label in the ConfigMap |
global |
- |
Cluster configuration |
"1" |
SuperPoD ID |
1 is used as an example. You can modify or add the configuration as required. After a SuperPoD is configured, NodeD will use its configuration, instead of the global configuration. |
activate |
|
Whether to enable pingmesh |
task_interval |
[1–60] |
Interval for executing a pingmesh task, in seconds. |
Network detection pingmesh results are logged to the <nodename>.log file. The following table describes the fields in the file.
Parameter |
Value Range |
Description |
|---|---|---|
uid |
A string of 64 characters |
ID of the pingmesh task |
config |
String |
User configuration of the pingmesh task |
physicID |
[0–15] |
Physical ID of the NPU |
taskID |
|
Task ID |
DestNum |
[0–47] |
Number of target addresses in the pingmesh task |
source_addr |
IPv4 network address |
Source address |
target_addr |
IPv4 network address |
Destination address |
suc_pkt_num |
- |
Number of packets that are successfully sent |
fail_pkt_num |
- |
Number of packets that fail to be sent |
max_time |
|
Maximum response time |
min_time |
|
Minimum response time |
avg_time |
|
Average response time |
tp95_time |
|
Response time at TP 95 |
reply_stat_num |
- |
Number of responses found in this query |
ping_total_num |
- |
Total number of responses in this task |
If a slow network fault is detected, the fault is reported to the public fault management center of ClusterD through gRPC.
The ConfigMap file displays related information, which is automatically cleared 5 seconds later.

Fault Code |
Fault Description |
Fault Level |
|---|---|---|
200001010 |
Slow network detected/recovered in a node |
NotHandleFault |
200001011 |
Inter-node slow network detected/recovered in a SuperPoD |
NotHandleFault |
200001012 |
Slow network not caused by a card fault |
NotHandleFault |