Node faults are detected by NodeD. These faults include node health status, node hardware faults, and DPC shared storage faults. The details are as follows:
After completing the node status diagnosis of a node, NodeD collects the fault information on the node. When a node is faulty, the node status reporting mechanism continuously sends the node status to Volcano (currently, only the hardware fault information on the node is collected).
NodeD sends a fault query request to iBMC through the IPMI driver. Then iBMC responds to NodeD with the current hardware alarm. NodeD collects the hardware alarm and reports the node hardware status to Volcano.
For nodes that use Scale-Out Storage DPC, you can use the noded-dpc-{version}.yaml file in the NodeD installation package to start the NodeD service and to enable detection and reporting of DPC process exceptions and insufficient memory exceptions.
When a node is faulty, NodeD reports the node health status and node hardware faults. If no fault occurs, the node is considered healthy by default.

To ensure the normal use of node fault detection, install Volcano, Ascend Operator, NodeD, and ClusterD.
Include job-level rescheduling, pod-level rescheduling, and process-level rescheduling.
Resumable training provides default fault levels and fault handling policies for different fault codes of node hardware faults. If you want to modify the fault handling policy, see Node Hardware Faults. However, do not change it unless otherwise specified.